Compass Safe Distance: min. 5 m
to prevent magnetic interference with navigational instruments
DK 6/T RAL 9016 MED
4260590186669
Mounting Instruction
Mount the bracket on the wall or ceiling with the appropriate screws for the surface.
Fix the speaker to the bracket with the supplied stainless steel nuts (M6) and align it.
Select the required power tapping on the back of the speaker.
Connect the lead-out connection cable to the 100V loudspeaker line with the correct polarity.
An integrated thermal fuse automatically disconnects the loudspeaker driver in the event of excessive
heat (e.g. due to fire or driver failure), preventing a short circuit across the 100V line.
Do not bypass or remove the thermal fuse under any circumstances.
Verify the integrity of the connection cable during periodic maintenance.