DK-SF 10/T-PG MED
barcode 4 260590 186560

Horn speaker for marine application, 10W power, certified MED/1.44b 

Mechanical Data
Colour RAL 7035
Dimensions 142x256 mm
Weight (net) 1,9 kg
Power 10/5/2,5/1,25 (20) W
Connector ceramic block
Terminal Diameter 3,2 mm
Maximum Cable Passage 8 mm²
Mounting mounting bracket
Environmental Category: Category B (IEC 60945 - Exposed Equipment)
0098/2026 (EU) 2026/1434, item No. MED/1.44b. SOLAS 1974 as
amended, Regulation II-2/12,21,22, III/4, 6 & X/3, LSA Code VII,
HSC Code 4,8, IMO MSC.1/Circ. 808, 1369/Add.1
suitable for:
  • Cargo ships
  • Passenger ships without SRtP
  • Passenger ships with SRtP
Compass Safe Distance: min. 5 m
to prevent magnetic interference with navigational instruments
DK-SF 10/T-PG MED
barcode 4 260590 186560
Mounting Instruction
  1. Mount the U-bracket on the ceiling with the appropriate screws for the surface.
  2. If necessary, remove the speaker enclosure from the U-bracket.
  3. Insert the loudspeaker cable through the cable entry of the previously removed rear wall of the housing.
  4. Connect the loudspeaker cable to the terminals 100V and COM.
    If necessary, select a different power tapping.
  5. Carefully reinsert the back panel into the housing.
EQ Settings
EQ Setting
Frequency
[Hz]
Relative level to
1000 Hz
[dB]
EQ Setting
Frequency
[Hz]
Relative level to
1000 Hz
[dB]
EQ Setting
Frequency
[Hz]
Relative level to
1000 Hz
[dB]
EQ Setting
Frequency
[Hz]
Relative level to
1000 Hz
[dB]
200800315+412500
250100-12400+816000
31,50125-12500+820000
400160-12630+625000
500200-8800+83150+4
630250-1100004000+8
800315+4125005000+12
100-12400+8160006300+12
An integrated thermal fuse automatically disconnects the loudspeaker driver in the event of excessive heat (e.g. due to fire or driver failure), preventing a short circuit across the 100V line. Do not bypass or remove the thermal fuse under any circumstances. Verify the integrity of the connection cable during periodic maintenance.