Compass Safe Distance: min. 5 m
to prevent magnetic interference with navigational instruments
DK-SF 10/T-PG MED
4260590186560
Mounting Instruction
Mount the U-bracket on the ceiling with the appropriate screws for the surface.
If necessary, remove the speaker enclosure from the U-bracket.
Insert the loudspeaker cable through the cable entry of the previously removed rear wall of the housing.
Connect the loudspeaker cable to the terminals 100V and COM. If necessary, select a different power tapping.
Carefully reinsert the back panel into the housing.
EQ Settings
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
20
0
80
0
315
+4
1250
0
25
0
100
-12
400
+8
1600
0
31,5
0
125
-12
500
+8
2000
0
40
0
160
-12
630
+6
2500
0
50
0
200
-8
800
+8
3150
+4
63
0
250
-1
1000
0
4000
+8
80
0
315
+4
1250
0
5000
+12
100
-12
400
+8
1600
0
6300
+12
An integrated thermal fuse automatically disconnects the loudspeaker driver in the event of excessive
heat (e.g. due to fire or driver failure), preventing a short circuit across the 100V line.
Do not bypass or remove the thermal fuse under any circumstances.
Verify the integrity of the connection cable during periodic maintenance.