Compass Safe Distance: min. 5 m
to prevent magnetic interference with navigational instruments
DK -SF 15/T-PG MED
4260590186577
Mounting Instruction
Mount the U-bracket on the ceiling with the appropriate screws for the surface.
If necessary, remove the speaker enclosure from the U-bracket.
Insert the loudspeaker cable through the cable entry of the previously removed rear wall of the housing.
Connect the loudspeaker cable to the terminals 100V and COM. If necessary, select a different power tapping.
Carefully reinsert the back panel into the housing.
EQ Settings
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
EQ Setting Frequency [Hz]
Relative level to 1000 Hz [dB]
20
0
80
0
315
+12
1250
0
25
0
100
-12
400
+12
1600
-4
31,5
0
125
-12
500
+8
2000
0
40
0
160
-8
630
+4
2500
0
50
0
200
0
800
-2
3150
0
63
0
250
+6
1000
0
4000
+8
80
0
315
+12
1250
0
5000
+12
100
-12
400
+12
1600
-4
6300
+12
To ensure uninterrupted operation of the public address and voice evacuation system
during a fault condition, this loudspeaker is equipped with integrated short-circuit protection:
A Ceramic Terminal Block ensures high-temperature resistance and electrical isolation of the input connection.
A Thermal Fuse automatically disconnects the loudspeaker driver in the event of excessive heat (e.g., due to fire or
driver failure), preventing a short circuit across the 100V line.
Do not bypass or remove the thermal fuse under any circumstances.
Ensure correct polarity when connecting to the ceramic terminal block.
Verify the integrity of protection components during periodic maintenance.