DL-S 15-100/T plus MED
barcode 4 260590 186232

2-way ceiling speaker for marine application, 15W power, certified MED/1.44b

Technical Data
Colour RAL 9016
Dimensions 242x108 mm
Ceiling Cut-out 210 mm
Dispersion -6dB, 500Hz h/v 180°/180°
Dispersion -6dB, 1KHz h/v 175°/175°
Dispersion -6dB, 2KHz h/v 170°/160°
Dispersion -6dB, 4KHz h/v 100°/35°
Frequency Range 100 - 16.900 Hz
Frequency Response 90 - 17.000 Hz
Power 15/7.5/3.75 (8) W
Environmental Category: Category B (IEC 60945 - Protected Equipment)
0098/2026 (EU) 2025/1533, item No. MED/1.44b. SOLAS 1974 as
amended, Regulation II-2/12,21,22, III/4, 6 & X/3, LSA Code VII,
HSC Code 4,8, IMO MSC.1/Circ. 808, 1369/Add.1
suitable for:
  • Cargo ships
  • Passenger ships without SRtP
  • Passenger ships with SRtP
Compass Safe Distance: 2.25 m (standard compass), 1.5 m (steering and emergency compass
to prevent magnetic interference with navigational instruments
DL-S 15-100/T plus MED
barcode 4 260590 186232
Mounting Instruction
  1. Create the necessary ceiling cut-out and check the installation depth.
  2. Remove the speaker grille, which is fixed by magnetic fastening.
  3. Guide the connection cable through the cable passage with the rubber grommet.
  4. Connect the speaker cable to the screw terminal at the front of the speaker. If necessary, use the rotary switch to select a different power adjustment.
  5. Plug the terminal into the pin strip on the front of the speaker.
  6. Attach a safety cable to the eyelet on the side of the speaker (not supplied).
  7. Insert the speaker into the ceiling until the speaker ring on the front touches the ceiling.
  8. Use the three installation screws on the side of the speaker to fix it in the ceiling.
  9. Reattach the speaker grille.
To ensure uninterrupted operation of the public address and voice evacuation system during a fault condition, this loudspeaker is equipped with integrated short-circuit protection:
A Ceramic Terminal Block ensures high-temperature resistance and electrical isolation of the input connection.
A Thermal Fuse automatically disconnects the loudspeaker driver in the event of excessive heat (e.g., due to fire or driver failure), preventing a short circuit across the 100V line.
Do not bypass or remove the thermal fuse under any circumstances.

Ensure correct polarity when connecting to the ceramic terminal block. Verify the integrity of protection components during periodic maintenance.