TS-C 06-140/T MED
barcode 4 260590 186362

Sound column for marine application, 6W power, certified MED/1.44b

Mechanical Data
Colour RAL 9016
Dimensions 161x101x123
Weight (net) 1,4 kg
Power 6/3/1,5 W
Connector Cable (1m)
Mounting mounting bracket
Environmental Category: Category A (IEC 60945 - Protected Equipment)
0098/2026 (EU) 2026/1434, item No. MED/1.44b. SOLAS 1974 as
amended, Regulation II-2/12,21,22, III/4, 6 & X/3, LSA Code VII,
HSC Code 4,8, IMO MSC.1/Circ. 808, 1369/Add.1
suitable for:
  • Cargo ships
  • Passenger ships without SRtP
  • Passenger ships with SRtP
Compass Safe Distance: 2.80 m (standard compass), 1.45 m (steering and emergency compass)
to prevent magnetic interference with navigational instruments
TS-C 06-140/T MED
barcode 4 260590 186362
Mounting Instruction
  1. Mount the swivel bracket on the wall.
  2. Fit the sound column on the swivel bracket.
  3. Unscrew the base of the sound column.
  4. Insert the incoming cable through the cable gland and connect it to the terminal.
  5. Screw the base back onto the sound column.
Cable lug
An integrated thermal fuse automatically disconnects the loudspeaker driver in the event of excessive heat (e.g. due to fire or driver failure), preventing a short circuit across the 100V line. Do not bypass or remove the thermal fuse under any circumstances. Verify the integrity of the connection cable during periodic maintenance.